+ Upload Boiler Manual (PDF) or Add Quick Field Cheat Note
🚨 Common UK Boiler Fault Codes Quick Reference
| Brand | Code | Meaning | First Checks on Site |
|---|
🔥 Gas Rate & Working Pressure Reference
Natural Gas (G20) Metric Meter Formula (2-Min Test)
1. Time 1 full revolution of the test dial (or measure m³ over 120 seconds).
2. kW Gross = (m³ in 2 mins × 30) × 10.76 | kW Net = kW Gross ÷ 1.11
3. Imperial (1 cu.ft dial): kW Gross = (3600 ÷ seconds for 1 rev) × 0.0283 × 10.76
- • Standing Pressure (NG): ~21 mbar (normal range 19–23 mbar)
- • Min Working Pressure at Meter Outlet: 19 mbar (21 mbar ± 2 mbar)
- • Max Permissible Pipework Drop (Meter to Appliance): 1.0 mbar
- • LPG (Propane G31) Working Pressure: 37 mbar
- • Tightness Test (NG Existing Installation): Let-by 1 min (7–10 mbar), Stabilisation 1 min, Test 2 mins (max drop 4 mbar if no smell of gas; 0 mbar on new pipework)
🌡️ Commissioning, FGA & Hydronic Cheat Sheet
- • Flue Gas Analyser (Condensing Combi Max Rate): CO₂ typically 8.7% – 9.6% (check MI), CO < 200 ppm, CO/CO₂ Ratio < 0.0040 (action at ≥ 0.0040, ID at ≥ 0.0080).
- • System Cold Fill Pressure: 1.0 – 1.5 bar (PRV lifts at 3.0 bar).
- • Expansion Vessel Pre-Charge: Set to static head + 0.2 bar (typically 0.8 – 1.0 bar with system drained/zeroed).
- • Condensing Boiler Flow/Return ΔT: Target 15°C – 20°C differential so return stays below 55°C for latent heat recovery.
- • Part L Heating Flow Temp (New/Replacement): Design max flow temperature ≤ 55°C.
- • Copper Pipe Carrying Capacity (Approx at 1m/s): 15mm ≈ 12 kW • 22mm ≈ 28 kW • 28mm ≈ 50 kW.